Advanced Technology Services, Inc.
Anticipated Operating Costs for a 100 Tons Per Day WG/TO System
|
Number of PRIMARY gasification cells |
ea |
6 |
|
Number of SECONDARY gas processors |
ea |
1 |
|
Average Space Requirement |
acres |
2.5 |
|
Total Pilots and Igniters |
ea |
13 |
|
Total LPG Consumption |
gal/hr |
4.5 |
|
Cost per Unit of Supplemental Fuel |
$/gal |
0.43 |
|
Total Supplemental Fuel Cost per Day |
$ |
46.82 |
|
Total Air Supply Fans and Blowers |
ea |
9 |
|
Total KWHr for Fans |
KW-Hr |
67 |
|
Other Miscellaneous Power Use |
KW-Hr |
1.8 |
|
Total Power Consumption |
KW-Hr |
68.8 |
|
Cost per Unit of Electrical Power |
$/KW-Hr |
0.06 |
|
Total Electrical Power Cost per Day |
$ |
99.07 |
|
Total Daily Admin. Hours Required |
Hrs. |
24 |
|
Admin Hourly Pay Rate ( Fully Burdened ) |
$ |
17.00 |
|
Total Daily Labor Hours Required |
Hrs. |
16 |
|
Labor Hourly Pay Rate ( Fully Burdened ) |
$ |
10.00 |
|
Total Payroll per Day |
$ |
568.00 |
|
Average Daily Misc. Expense |
$ |
29.18 |
|
Total Daily Operating Cost |
$ |
743.07 |
|
Total Operating Cost per Ton of Waste |
$ |
7.43 |
The amounts used to calculate this operating cost are based on costs for labor, fuel and electricity in central Kentucky for a 100 tons per day system. To find out what your operating costs would be, just fill out our Waste Survey Form. We'll be happy to provide you with a proposal designed to meet your individual needs and help eliminate your waste disposal problems!